Products

M5-IC

An Intelligent Control Device for the Replacement of the Casi PX, PXN and PXNplus CPU Controller.
Bridge to Open Access Control

FAQs

Which controller do you need?
Please refer to the linked document "Controllers Comparison Chart"
Are the WIU devices supported?
Yes, the Wiegand Interface Units (WIU) devices are supported. Both the WIU-2 and WIU-4 devices can be used with the Mercury products that support the F2F reader protocol.
What voltage of surge protection should be used on inputs, outputs, readers and communications circuits?
Input circuits: minimum working/service voltage: 12 volts Output circuits (switching DC): minimum working/service voltage: 30 volts Reader data lines: minimum working/service voltage: 5 volts Reader power: minimum working/service voltage: as required by reader RS-232 communication: minimum working/service voltage: ±25 volts RS-485 communication: minimum working/service voltage: ±7 volts Ethernet (non PoE): minimum working/service voltage: 5 volts PoE: minimum working/service voltage: 60 volts